Rental of mobile boiler rooms CONUS
STEPS TO BE TAKEN BY PERSON INTERESTED IN LEASE
- PERSON INTERESTED will complete the questionnaire about mobile boiler room CONUS and send it by E-mail
- EUROCONUS will check its leasing schedule to see if it can accommodate the request of the PERSON INTERESTED
- EUROCONUS will E-mail an offer (or request rejection) to the PERSON INTERESTED within 3 to 5 days
- offer is to be valid for 15 days, for which EUROCONUS will make a guaranteed reservation of the subject boiler plant in the time schedule
- guaranteed reservation of boiler plant expires in 15 days and the PERSON INTERESTED will be informed accordingly by E-mail
-
if the PERSON INTERESTED does not make an agreement within 15 days (or does not at least send a purchase order), EUROCONUS will not further guarantee validity of the offer and will offer the boiler plant to other PERSONS INTERESTED
IMPORTANT NOTICE
CAPACITY OF BOILER PLANTS
the boiler plant lease is always to be contracted for specific terms based on available capacity, therefore, it is always required to state the required terms in the enquiry
ADVANCE OF PURCHASE ORDER
we recommend contracting the lease of mobile boiler plants several months in advance, or even a year ahead, as the lease is thoroughly scheduled several months or even several years in advance!!!
RENTAL PRICE
THE RENTAL PRICE IS DEPENDENT ON
the selected boiler room type and the rental period
PRICE INFORMATION
we will always provide you with a written offer based on reciept of a questionnaire about mobile boiler room CONUS inquiry, the rental price usually reaches approx. 2 000 € per month, by the largest sources it can be also approx. 15 000 € per month
RENTAL COST IS CALCULATED
from the date when boiler room was set up on its destination place - if boiler room hasn't been used for a full month, the rental cost is calculated proportionally according to the number of days in the incomplete month since the boiler room has been delivered
RENTAL CONDITION
THE RENTAL FEE INCLUDES
INSURANCE
insurance of the subject of rental against natural threaths (excl. flood areas)
SERVISE INSPECTION
regular annual boiler room inspection, revision and service
INITIAL COMMISSIONING
the initial commissioning of the subject of rental, operator training
FAULT SERVICE
24/7 in case of fault (unnecessary visits of our technician caused by the customer are subject to a charge)
THE RENTAL FEE DOES NOT INCLUDE
BASE PREPARATION
preparation of the base for the boiler room installation
BOILER ROOM CENNECTION
installation and connection of the boiler room to individual media
OPERATION
operation of the subject of rental by an operator
OPERATING MEDIA
media necessary for operation (fuel, electrical power, GSM service for evaluation of fault of the subject of rental etc.)
BOILER ROOM TRANSPORT
transport of boiler room from the place of its actual use, eventually from other place where the boiler room is stored, to a place specified by the customer, where the boiler room will be installed as a subject to rental
LOADING AND UNLOADING OF BOILER ROOM BY CRANES
loading of boiler room by a crane or 2 cranes (according to the size of boiler room) from the place of its original location and unloading of boiler room on the place specified by customer
PROJECT DOCUMENTATION OF THE INSTALLATION OF BOILER ROOM
project documentation of the installation of boiler room is realized according to the valid norms before or during the boiler room construction, based on the local situation, and it is realized by customer at his own costs or, if both sides agreed, by renter at the costs of customer and in close cooperation with customer
ENGINEERING ACTIVITY
engineering activity is realized by customer at his own costs or, if both sides agreed, by renter at the costs of customer and in close cooperation with customer
POSSIBILITY TO PROVIDE RENTAL INCLUDING OPERATING SERVICES
We have by our partner TZB Orlova currently operates a control centre for continuous supervision of operation of thermal, gas and technological devices. These optimal conditions enable us to provide operation and servicing on the highes qualitative level, usually for lower operating costs, at the customer’s site. We are able to provide this service in case of your interest. The price depends on conditions and location of the boiler room. You can indicate your interest in operation of the rented boiler room in the questionnaire.
Equipment of mobile boiler rooms CONUS MKOD - gas steam
STANDARD EQUIPMENT OF MODERATED PRESSURE MOBIL BOILER ROOMS CONUS MKOD 8000 - GAS STEAM
HEATING PART
safety elements, steam fittings, operating pressure 12,2 bar, heat-delivery surface 189 m2, steam temperature 192 °C
WATER PART
chemical water treatment, automatic dosing, feed tank and pumps, fittings, feed water temperature 105 °C
FUEL PART
gas supply to the burner (natural gas or propane), gas pressure control, fuel emergency lock with gas pressure control RMG 330, fittings, gas pressure behind gas pressure control 5,0 kPa, automatics type KAH - RAY - TMG 740-2, gas equipment mobil boiler room KAH, slot burner RAY - UEN 3 SP-SL, rated power of a burner 5 350 kW, regulable power approximately 1 100 - 5 600 kW ( 1 600 - 8 000 kg steam / hour )
ELECTRICAL PART
steam pressure based control, lighting, 400 V / 230 V / 42 kW
OPERATION
continued attendance, possibility of remote control from control centre and PC visualization by request
CONTAINER - 1 pc
thermally uninsulated, blue color, possibility of own heating with own warm-air furnace, dimensions: length 9,35 till 10 m - width 2,85 m - height 4,75 m, at the transport 3,7 m
SMOKE STACK
smoke stack DN 500 or 600 mm, 3 component stack ( stainless steel - heat insulation - aluminum ), high according at need up until 40 m, eventually steel self contained, approximately like high
BOILER
there is 1 pc of a steam boiler - KAH - BK 8,0 T 80 – with power 8 000 kg steam / hour
DOCUMENTATION
inspection books and proposed operating and maintenance rules are supplied with the boiler room
TECHNICAL CONDITIONS
GAS
gas inlet approximately 90 - 100 kPaCONDENSATE
return rate over 50%, temperature over 80°C
SLUDGE BLOW-OFF
automatic, eventually manual operation
CUSTOMER REQUIREMENTS
INQUIRY
in case you are interested in our services, send us a written inquiry - questionnaire for mobile boiler rooms CONUS
BASE
useful base has to be prepared hard but is it not necessary exactly level surface for our containers with weight approx. 5 till 30 tons - a standard hard level surface is adequate eventually only a concrete, an asphalt, a garth or panels, ties, concrete footing, etc. - it is not necessary a field engineering and it is saving of costs compared to past or to other containers
TRANSPORT
we solving a transport and unloading of the boiler room, eventually a customer after the agreement
MEDIA
gas, heating medium, water and power connections to be solved by the customer, eventually we after the agreement
OTHER INFORMATION
RENTALS
have to be agreed individually according to the current usage of rented boiler rooms in the given period
SERVICE
in the Slovak Republic and in the Czech Republic provided by CONUS Group, abroad provided by contractual partners
DELIVERY TIME
16 – 20 weeks
PROJECT DOCUMENTATION
we provide an orientation project documentation for location of mobil boiler room in the event of interest
Equipment of mobile boiler rooms CONUS - coal warm-water
STANDARD EQUIPMENT OF MOBIL BOILER ROOMS CONUS - COAL WARM-WATER ( for WOOD PELLETS also )
HEATING PART
max. operating pressure of 2 bar, mixing valve, expander, safety elements, pumps, fittings
WATER PART
water softening, automatic re-filling, max. operating pressure of 10 bar
FUEL PART
fuel storage in a one day hopper, automatic worm feeder as part of the boiler
ELECTRICAL PART
equithermal control, 1 mixing circuit, WSW heating control, lighting, grounding, 230 V / 5 kW
OPERATION
sporadic attendance, information on emergency conditions sent via GSM, possibility of remote PC visualization
CONTAINER - 1 pc
thermally insulated, include a floor, rigid structure with stability for broken terrain, the tonnage is 26 tons, a floor is from laminated bamboo-wood or from steel with nonskud surface, blue color, a stacking 8 pcs, a length from 2 till 13 m, a width from 2 till 3 m, a height from 2 to 3,5 m, the best quality of lacker in worldmarket, fire resistence
SMOKE STACK
4 meter high, self supporting, 3 component stack (stainless steel - heat insulation - aluminum)
BOILERS
there are different types of boilers, you can find here, e.g. 2 pcs of steel EKO KOMFORT boilers – these are automatic boilers with a retort burner and automatic fuel dosing ( from a hopper ), with a combustion air fan that supports quality combustions, the boiler complies with strict European emission limits, boiler efficiency of 82 to 86%, max. output temperature of 80°C, the boiler automatically controls the stability of combustion
DOCUMENTATION
inspection books and proposed operating and maintenance rules are supplied with the boiler room
AUTOMATIZATION FEATURES FOR EXTRA CHARGE
COAL CHARGING
individual sollution – e.g. belt conveyors, chutes, etc.
ASH DISCHARGE
individual solution – e.g. by worm conveyor into an enclosed container
HEATING PART
max. operating pressure of 6 barwith a plate heat exchanger
WSW PREPARATION
WSW preparation rates can be added to a boiler or delivery separately to your needs
CUSTOMER REQUIREMENTS
INQUIRY
in case you are interested in our services, send us a written inquiry - questionnaire for mobile boiler rooms CONUS
BASE
useful base has to be prepared hard but is it not necessary exactly level surface for our containers with weight approx. 5 till 30 tons - a standard hard level surface is adequate eventually only a concrete, an asphalt, a garth or panels, ties, concrete footing, etc. - it is not necessary a field engineering and it is saving of costs compared to past or to other containers
TRANSPORT
we solving a transport and unloading of the boiler room, eventually a customer after the agreement
MEDIA
fuel storage, heating medium, water and power connections to be solved by the customer, eventually we after the agreement
OTHER INFORMATION
RENTALS
have to be agreed individually according to the current usage of rented boiler rooms in the given period
SERVICE
in the Slovak Republic and in the Czech republic provided by CONUS Group, abroad provided by contractual partners
DELIVERY TIME
10 – 12 weeks
PROJECT DOCUMENTATION
we provide an orientation project documentation for location of mobil boiler room in the event of interest
Types of mobile boiler rooms CONUS - oil warm-water

MOBILE OIL WARM-WATER BOILER ROOM CONUS - container type
CAST IRON or STEEL BOILERS - 2 pcs, eventually 1 pc
The 2nd boiler is 100% reserve in mobil boiler rooms CONUS MKOOK. The power of mobil boiler rooms for one boiler
( 2 boilers ) is in table. Double power of one boiler is possible according request.
boiler room type | power (kW) | fuel | type of boiler | pc |
---|---|---|---|---|
CONUS MKOOA 100 | 50 (100) | oil | ACV 50 | 2 |
CONUS MKOOK 320 | 160 (320) | oil | KTU 160 | 2 |
CONUS MKOLB 340 | 170 (340) | oil | BUDERUS 170 | 2 |
CONUS MKLB 350 | 350 | oil | BUDERUS 350 | 1 |
CONUS MKOV 460 | 460 | oil | VIESSMANN 460 | 1 |
CONUS MKOOK 500 | 250 (500) | oil | KTU 250 | 2 |
CONUS MKOLB 560 | 280 (560) | oil | BUDERUS 280 | 2 |
CONUS MKLD 750 | 750 | oil | De DIETRICH 750 | 1 |
CONUS MKOOK 800 | 400 (800) | oil | KTU 400 | 2 |
CONUS MKOLB 920 | 460 (920) | oil | BUDERUS 460 | 2 |
CONUS MKOOK 1300 | 650 ( 1 300) | oil | KTU 650 | 2 |
CONUS MKOB 1300 | 1 300 | oil | BUDERUS 1300 | 1 |
CONUS MKOLB 1370 | 685 ( 1 370) | oil | BUDERUS 685 | 2 |
CONUS MKOD 1800 | 1 800 | oil | KDVE 1800 | 1 |
CONUS MKOLB 1820 | 910 (1 820) | oil | BUDERUS 910 | 2 |
CONUS MKOOK 2000 | 1 000 (2 000) | oil | KTU 1000 | 2 |
CONUS MKOLB 2040 | 1 020 (2 040) | oil | BUDERUS 1020 | 2 |
CONUS MKOL 2500 | 2 500 | oil | LOOS 2500 | 1 |
CONUS MKOLB 2600 | 1 300 (2 600) | oil | BUDERUS 1300 | 2 |
CONUS MKOOK 3200 | 1 600 (3 200) | oil | KTU 1600 | 2 |
CONUS MKOOK 5000 | 2 500 (5 000) | oil | KTU 2500 | 2 |
CONUS MKOOK 7000 | 3 500 (7 000) | oil | KTU 3500 | 2 |
CONUS MKOOK 8000 | 4 000 (8 000) | oil | KTU 4000 | 2 |
CONUS MKOOK 10000 | 5 000 (10 000) | oil | KTU 5000 | 2 |
CONUS MKOOK 12000 | 6 000 (12 000) | oil | KTU 6000 | 2 |
One steel boiler is in container CONUS MKOOA, CONUS MKOV, CONUS MKOB and CONUS MKOL.
One cast iron boiler is in container CONUS MKLB and CONUS MKLD.
One steel boiler and one cast iron boiler are in container CONUS MKOLB.
Two steel boilers are in container CONUS MKOOK.
A fuel is a oil or a diesel, after exchange of a burner a natural gas or a propane.
![]() |
![]() |
these mobile boiler rooms CONUS are the boilers and a fuel oil storage together in 1 container now
boiler room type | power (kW) | fuel | type of boiler | pc |
---|---|---|---|---|
CONUS MKOOA 100 | 50 (100) | OSC 2000 | ACV 50 | 2 |
CONUS MKOLB 340 | 170 (340) | OSC 4500 | BUDERUS 170 | 2 |
CONUS MKLB 350 | 350 | OSC 3000 | BUDERUS 350 | 1 |
CONUS MKOV 460 | 460 | OSC 2000 | VIESSMANN 460 | 1 |
CONUS MKOLB 560 | 280 (560) | OSC 4500 | BUDERUS 280 | 2 |
CONUS MKLD 750 | 750 | OSC 2000 | De DIETRICH 750 | 1 |
CONUS MKOLB 920 | 460 (920) | OSC 4500 | BUDERUS 460 | 2 |
OIL STORAGE CONUS OSC WITH BOILER(S) IN 1 CONTAINER
OIL STORAGE CONUS OSC 1000 | 1 000 litres |
---|---|
OIL STORAGE CONUS OSC 1500 | 1 500 litres |
OIL STORAGE CONUS OSC 2000 | 2 000 litres |
OIL STORAGE CONUS OSC 3000 | 3 000 litres |
OIL STORAGE CONUS OSC 3500 | 3 500 litres |
OIL STORAGE CONUS OSC 4500 | 4 500 litres |
![]() |
![]() |
![]() |
OIL STORAGE WITHOUT BOILER(S) IN 1 SEPARATE OIL CONTAINER CONUS OKC
OIL CONTAINER CONUS OKC 6000 | 6 000 litres |
---|---|
OIL CONTAINER CONUS OKC 7500 | 7 500 litres |
OIL CONTAINER CONUS OKC 9000 | 9 000 litres |
OIL CONTAINER CONUS OKC 12000 | 12 000 litres |

OIL STORAGE - 1 SEPARATE DOUBLE-CUP OIL TANK CONUS ONC FOR A BIG POWER OF BOILERS